Diagbox 8.55 Download

Diagbox 8.55 (v07.855) + PP2000 V25 (v24.99) and Lexia3 V48 (v47.99) for Citroen/Peugeot Diagbox v8.55. VMware 12 image with XP Pro SP3 32bit English – PSA XS Evolution Interface Drivers – PSA XS Evolution Interface Automatic Firmware 4.3.7 updating, Launcher850 by Simple – Diagbox Language Switcher – Diagbox Killer. Moved Permanently. The document has moved here.

This article show the guide on how to install DiagBox v8.01 diagnostic software.This method provided by the cartechnology remember simple,big thanks to him selfless work.

Note: If using a Virtual Machine, ensure Virtualization is enabled in the physical laptop BIOS.

Preparation for Installing DiagBox 8.01 on Notebooks and VMWare Workstation
– Starting with any (32 bit) Windows (preferably XP or 7), install .NET 3.51 and Windows drivers or VMWare Tools (if on VMWare Workstation or Player).

Preparation for Installing DiagBox 8.01 on VirtualBox
– Settings –> System: Motherboard, ensure APIC is OFF, use one processor and enable Virtualization. Allocate enough memory for VM.
– Having installed 32 bit Windows + VirtualBox Guest Additions + .NET 3.51, use the Powershell Command “Get-WMIObject win32_BIOS” or the “DMIdecode” tool to obtain BIOS information (not essential).
– Close VirtualBox and start an administrator’s CMD, navigate to “C:Program FilesOracleVirtualBox” and execute the following command (Replacing “Your VM” with your Virtual Machine’s name, and System Serial with your hardware’s or any code or text such as “CDN29326BH”):
C:Program FilesOracleVirtualBox>VBoxManage setextradata “Your VM” “VBoxInternal/Devices/pcbios/0/Config/DmiSystemSerial” “System Serial”

Installing DiagBox 8.01
1- Install DiagBox 7.01 and restart DiagBox to run update 7.02. Install update 7.xx-7.57 (this will create “C:AWRootdtwrcfgConfig.sys”).
2- Install “VC++ 2008 Redistributable Package”, a copy will be available in “C:teleassistancevisualCvcredist_x86.exe” after installing DiagBox.
3- Restart the computer and use “Kill_DiagBox_Tasks.bat” to stop related processes and rename “C:AWRoot” to “C:AWRoot7”
4- Run DiagBox 8.01 installation (it will uninstall v7.xx first) until it requests Activation. Close it (X) and run the tool “AWRoot_v7_Conf+Ativation_v8.exe” it will copy configuration from “C:AWRoot7..” and inject the necessary files.
5- Run DiagBox again, it should continue the installation successfully.

Done !,

Restart DiagBox 8.01 as Administrator to confirm all is well (don’t be concerned about the reported version and do not start Lexia or PP2000 yet). If you face an issue, run the activation tool again and/or review “Versions” below.

If DiagBox runs fine, ensure you keep a backup copy of the file “C:AWRootbinfiAPPDIAG.SYS” in a safe location.

Installing Updates
1- Download and install “DiagBox_updt_802.ISO” update.
2- Download and install subsequent v8.xx updates or Maitresox updates (from 7.66+).

Tool you need:

DiagBox Full v8.01 ISO:

AWRoot_v7_Conf+Ativation_v8.exe No password

DiagBox updates working with DiagBox V8.01 based on v7.xx profile, Extraction Password: Simple

DiagBox_updt_802_Simple.exe

DiagBox_updt_803-810_Simple.exe

DiagBox_updt_811-814_Simple.exe

DiagBox_updt_815-817_Simple.exe

For those who wish to stay with (ISO 639-1) standard:

DiagBox_updt_803-808_Simple.exe (7.72) Password: Simple #808

And those who wish to continue further:

DiagBox_updt_810_Simple.exe (7.74) No Password

Cache Contents Restorer No password

Kill_DiagBox_Tasks

Versions
DiagBox will run and display the (8.xx or 7.xx) version number listed in “AWRootbinfiversion.ini” file. However, Lexia or PP2000 will fail to operate with “version.ini” set to “08.xx” and “APPDIAG.SYS” will be corrupted and will need to be restored before DiagBox will work again.
So, for DiagBox, Lexia and PP2000 to operate, set the version to “7.xx” or “7.xxx” (07.81 or 07.817 can be set to indicate the true DiagBox 8 version).
[APPLICATION]
version=07.817

It is possible to operate Lexia/PP2000 (after starting DiagBox with 8.xx) by starting DiagBox while having “version.ini” listing the 8.xx only (or first), then changing it to 7.xx or commenting the line “version=08.xx” and saving BEFORE starting LEXIA or PP2000 as shown below.
[APPLICATION]
;version=08.01
version=07.65

Updates
– DiagBox v7 and v8 install and run on all x86 (32bit) Windows including 10 TH1, TH2, RS1 and RS2.
– Entering a System Serial for the Virtual Machine (as described above) resolves the “psaAagent.exe” and the missing tabs issue on VirtualBox.
– If you get “Error 2” after restarting DiagBox, try commenting “version=8.xx” in “version.ini” before restarting DiagBox again.

P.S. DiagBox has been running on Firmware 4.3.4 since 7.66/8.02.

Someone put the full installation process on the net, just edit “version.ini” as described above.

(Visited 423 times, 2 visits today)
Content includes: VMware 12 image with XP Pro SP3 32bit English and pre-activated Diagbox 8.55 (v07.855) Multilanguage ; as well as VMware 12 image with XP Pro SP3 32bit English and pre-activated PP2000 V25 and Lexia3 V48 Multilanguage.
Part 1: VMware 12 image with XP Pro SP3 32bit English and pre-activated Diagbox 8.55 (v07.855) Multilanguage
- VMware 12 image with XP Pro SP3 32bit English
- Diagbox 8.55 (v07.855) Multilanguage | 09/2017 (20 languages: Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Italian, Japanese, Hungary, Polish, Portuguese, Russian, Slovenian, Spanish, Swedish and Turkish)
- PSA XS Evolution Interface Drivers
- PSA XS Evolution Interface Automatic Firmware 4.3.7 updating, Launcher_850 by Simple
- Diagbox Language Switcher
- Diagbox Killer

Diagbox Crack


- PSA Interface Checker + All Firmware's from 2.0.1 to 4.3.7
- Backup APPDIAG.sys activation file in Desktop
Info of Launcher_850:
Contents of the 'C:AWRootbinlauncher' folder, this release includes firmware versions:
LX = Lexia and PP2000
DB = DiagBox
APPLI.COM
APPLI_4.2.0 LP.COM
APPLI_4.2.2 LP.COM
APPLI_4.3.0 DB.COM
APPLI_4.3.2 DB.COM
APPLI_4.3.3 DB.COM
APPLI_4.3.4 DB.COM
APPLI_4.3.5 DB.COM
1- Make a backup of all files in your 'C:AWRootbinlauncher' folder, no need to include folders inside launcher.
2- Extract all files of the 'launcher850.zip' into 'C:AWRootbinlauncher' overwriting existing files.
3- Connect your XS Evolution VCI and start DiagBox
4- DiagBox will check current firmware version and (upgrade/downgrade) using the file APPLI.COM, if necessary.
To change the Firmware version, rename the desired Firmware file from APPLI_X.X.X.COM to APPLI.COM.
launcher850.zip 17.9 MB
https://mega.nz/#!N1kA3bza!qgrVOsWJQZJIW1QwUOXVl8MAbZuhO6gdf-EOKO3-E6M
The update function can be disabled by setting 'MAJ_COM=TRUE' to 'MAJ_COM=FALSE' in 'C:AWRootbinLauncherap.ini'

Diagbox 8.55 Download Full

In case reverting to the original setting is needed,
1- Delete all files (only) inside 'C:AWRootbinlauncher'.
Diagbox2- Restore backed-up files back to their original state.
Simple.
Part 2: VMware 12 image with XP Pro SP3 32bit English and pre-activated PP2000

Diagbox 8.55 Download Pc

V25 and Lexia3 V48 Multilanguage
- VMware 12 image with XP Pro SP3 32bit English
- PP2000 V24.99 [V25] Multilanguage (24 languages: Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hebrew, Indonesian, Italian, Japanese, Hungary, Norwegian, Polish, DiagboxPortugueseDiagbox, Russian, Slovenian, Spanish, Swedish, Thai and Turkish)
- Lexia3 V47.99 [V48] Multilanguage (20 languages: Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Italian, Japanese, Hungary, Polish, Portuguese, Russian, Slovenian, Spanish, Swedish and Turkish)

Psa Diagbox

- PSA XS Evolution Interface Drivers
- Lexia3/PP2000 Language Switcher
- KeyGen
Unzip using 7-Zip and run with VMware Player version 12 onwards.
All software's activated and PSA XS Evolution interface USB drivers installed.
When open these to your VMware use 'I moved it' option, then pre-activated Diagbox works. PP2000/Lexia3 might need re-activate using included KeyGen. If needed see Youtube video (https://www.youtube.com/watch?v=zl_wGpxcOzA&feature=youtu.be), how to activate PP2000 with KeyGen (https://www.youtube.com/watch?v=YanWwNn_fiU)
No password required, Reputation, Thanks or Donations are appreciated!
You can change the Diagbox/Lexia3/PP2000 language using my PSA Language Switcher tools (Read details in the following parts).
VMware - Diagbox V8.55 [v07.855] 2019.03.12https://mega.nz/#F!sY0hAaSD!GSwZALpZDzKJey5M7HQDRghttps://www.dropbox.com/sh/e1de8vzspiyp7zd/AACTHSZBjd5Otcc1MiFb4jMRa?dl=0 VMware - PP2000 V24.99 [V25] & Lexia3 V47.99 [V48] 2019.03.12https://mega.nz/#F!wZE0UYaT!yOWkd_S2LETLiaIYZ7Jhfwhttps://www.dropbox.com/sh/qxs8xa99khei8ri/AAChbj44eOCr60ZtOvW9YvQ7a?dl=0
Info on PSA Language Switcher:

Diagbox 8.55 Download Free

Under the link you can find my handy tools to change/switch PSA Diagnostic tools (DiagBox, Lexia3 and PP2000) language without installing it again.

Diagbox 8.55 Download


Just download and run the xxx Language Switcher.exe tool to switch the DiagBox, Lexia3 or PP2000 language.
Tool will set DiagBox, Lexia3 or PP2000 language to what user selected and also it will change backup language to 'English'.
There is own tool for each program:Download
DiagBox Language Switcher
https://mega.nz/#!4Z9TmCYK!TjwLqSDAeWikutw3jj_6rSZVxjXxLAsnZwlbWGb6QIQ

Lexia3 Language Switcher

https://mega.nz/#!ZQl1hIQD!2TufHvwgU6Jh9eVsEX-Ojc8pvlMjZfUuV8R3slv08Bk

PP2000 Language Switcher

Diagbox 9.68

https://mega.nz/#!pEt3CACB!VR28KHD0q1ASKEcwMccyMjx84ORgVsvzEGDk-Zf6SXk